    [Request Broker]

    Parameter Default Comment
    BinaryDirectory Absolute path to the bin directory which has the Broker program. Example: /home/openlink/openlink/bin
    CommandLine The command line parameters to use as a default. These parameters are also passed on to each program referenced in [Persistent Services]
    Protocols tcp Name of protocol to use tcp/spx/DECnet
    MaxAgents 0 if >0, maximum number of processes spawned by broker
    MaxConnections 0 if >0, maximum number of connections from clients
    HostNameResolver Yes Resolve IP addresses to hostnames Yes/No. Use Yes to give a more readable name in the logs. Set to No to avoid possible delays when frequently looking up unknown (new) IP numbers through a distant uncached DNS table. This parameter will have a direct affect on the type of match that is to be used for the StartupBy, ShutdownBy and ShutdownFrom parameters under the Security section.
    LingerTimeout 0 if >0, time in seconds that a disconnected agent will linger ready for re-use before giving up, and terminating.