Error Messages (U)

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #


Unable to create raw socket: permission denied

If you receive "unable to create raw socket" errors, take the following action:

1. cd into the /bin sub-directory of your OpenLink server components installation. For example:

$ cd /usr/openlink/bin


2. su to root.

3. Run the following command:

$ ./security -s


This should alleviate the problem. A non-privileged user may continue to administer the Broker. However, the actual Broker process will run with root permissions. This will allow it to create sockets.


Evidence

Session Rules Book
Request Broker Log
Request Broker Version String