    Error Messages (#)

    A B C D E F G H I J K L M N O P Q R S T U V W X Y Z #

    -1829 Errors

    The Informix error -1829 occurs when a system is unable to load the file $INFORMIXDIR/msg/citoxmsg.pam. To rectify this situation, all users should set the INFORMIXDIR environment variable using the Unix commandline or the Windows System utility.

    Multi-Tier users should also perform the following configuration change:

    1. Login to the machine that contains the OpenLink server components installation.

    2. Use a text editor to open the oplrqb.ini file that appears in the bin sub-directory of the OpenLink installation.

    3. Locate the [Environment INFORMIX] section that corresponds to their OpenLink driver version. For example:

    [Environment INFORMIX73]

    4. Ensure that INFORMIXDIR is present, uncommented, and set to the appropriate directory. For example:

    [Environment INFORMIX73]
    INFORMIXSERVER = openlink
    INFORMIXDIR = /dbs/informix/32bit/v73
    


    5. Save any changes and exit the file.

    6. Restart or reinitialize (oplshut +reinit) the Request Broker process to register changes.

    7. Test.